Energy regenerative: Battery pack discharge energy can be fed back to the enterprise power grid, and be used to regenerate between equipment channels as well, minimizing the load on the power grid, achieving geothermal energy output,reducing production costs |
Work condition simulation test according to actual road conditions:
It is possible to convert the actual on-board test condition data into a test process to simulate the working conditions of the power pack to help users develop their own unique test condition models. |
Various output function program settings: with constant current mode, constant voltage mode, constant current to constant voltage test, pulse mode, constant resistance mode, constant power mode, step mode, voltage ramp mode, current ramp mode, variable power mode, cycle, static and other work-step designs. |
Index | Parameter |
Current range | Max.3600A in parallel |
Current accuracy | 0.5‰FSR |
Voltage range | 5V~1000V(0V /negative are customizable) |
Voltage accuracy | 0.5‰FSR |
Rise time | 3ms(10%~90%) |
Switch time | 6ms(+90%~-90%) |
Data Acquisition time | 1ms |
THD | ≤5% |
Power | 30~800kW |
Power accuracy | 2‰FSR |